EASTMAN KODAK COMPANY -- 146 4254 HYPO CLEARING AGENT, CONCENTRATE -- 6750-00-920-7859
=====================  Product Identification  =====================

Product ID:146 4254 HYPO CLEARING AGENT, CONCENTRATE
MSDS Date:03/19/1997
FSC:6750
NIIN:00-920-7859
=== Responsible Party ===
Company Name:EASTMAN KODAK COMPANY
Address:343 STATE STREET
City:ROCHESTER
State:NY
ZIP:14650
Country:US
Info Phone Num:716-477-3194
Emergency Phone Num:716-722-5151
CAGE:19139
=== Contractor Identification ===
Company Name:BADGER GRAPHIC SALES INC
Address:1225 DELANGLADE ST
Box:46
City:KAUKAUNA
State:WI
ZIP:54130-0046
Country:US
Phone:414-766-9332
CAGE:0E4P0
Company Name:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
Address:343 STATE ST
Box:City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Phone:716-722-5151/(800) 242-2424
CAGE:19139
Company Name:EASTMAN KODAK CO US CUSTOMER SERVICE/GOVERNMENT SALES
Address:800 LEE RD
Box:City:ROCHESTER
State:NY
ZIP:14650-3129
Country:US
Phone:800-828-6203
CAGE:5K871

=============  Composition/Information on Ingredients  =============

Ingred Name:SODIUM SULFITE
CAS:7757-83-7
RTECS #:WE2150000
Fraction by Wt: 75-80%
Other REC Limits:NONE RECOMMENDED

Ingred Name:SODIUM METABISULFITE
CAS:7681-57-4
RTECS #:UX8225000
Fraction by Wt: 15-20%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3
ACGIH TLV:5 MG/M3; 9596

Ingred Name:SODIUM CITRATE
CAS:68-04-2
Fraction by Wt: 1-5%
Other REC Limits:NONE RECOMMENDED

Ingred Name:TETRASODIUM ETHYLENE DIAMINE TETRAACETATE
CAS:64-02-8
RTECS #:AH5075000
Fraction by Wt: 1-5%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT) IS 1600 MG/KG
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:CONTACT MAY CAUSE EYE BURNS.
    PROLONGED/REPEATED SKIN CONTACT MAY CAUSE IRRITATION OR BURNS; MAY
    CAUSE ALLERGIC REACTION. INHALATION MAY CAUSE IRRITATION OF MUCOUS
    MEMBRANES/UPPER RESPIRATORY TRACT. MA Y BE HARMFUL IF SWALLOWED,
    MAY CAUSE BURNS TO GI TRACT.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO KNOWN
    CARCINOGENS OR SUSPECT CARCINOGEN.
Effects of Overexposure:EYES-BURNS. SKIN-IRRITATION, BURNS, ALLERGIC
    REACTION. INHALED-DIFFUCULT BREATHING, IRRITATION OF MUCOUS
    MEMBRANES/UPPER RESPIRATORY TRACT. INGESTED-BURNS TO GI TRACT.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHALATION-IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
    ATTENTION IF SYMPTOMS OCCUR. EYES-FLUSH WITH WATER FOR 15 MINUTES.
    GET MEDICAL ATTENTION IF SYMPTOMS OCCUR. SKIN-IMMEDIATELY FLUSH
    WITH WATER	FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION IF
    SYMPTOMS OCCUR. INGESTED-DO NOT INDUCE VOMITING! IF CONSCIOUS,
    DRINK A GLASS OF WATER. CALL PHYSICIAN OR POISON CONTROL CENTER
    IMMEDIATELY.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS &
    PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
    DECPMOISTION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
    OTHERWISE, SWEEP UP AND PLACE IN A CONTAINER FOR CHEMICAL WASTE.
    CLEAN SURFACE THOROUGHLY TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CONTAINER CLOSED. KEEP AWAY FROM
    INCOMPATIBLE SUBSTANCES.
Other Precautions:USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
    HANDLING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
    OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH APPROVED RESPIRATOR OR
    AN AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED. USE IAW 29 CFR
    1910.134.
Ventilation:GOOD GENERAL VENTILATION SHOULD BE USED. VENTILATION RATES
    SHOULD MATCH THE CONDITIONS. RATE SHOULD MATCH THE CONDITION.
Protective Gloves:IMPERVIOUS GLOVES SHOULD BE WORN.
Eye Protection:SAFETY GLASSES WITH SIDE SHIELD
Other Protective Equipment:GOOD INDUSTRIAL HYGIENE PRACTICES SHOULD BE
    FOLLOWED WHICH INCLUDES PREVENTING EYE CONTACT & MINIMIZING SKIN
    CONTACT.
Work Hygienic Practices:EYE BATH, WASHING FACILITIES, SAFETY SHOWER.
    WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
FOR THE WORKING SOLUTION, SEE PNI W THIS NSN/CAGE. MSDS PRESENTED BY
    CAGE 0E4P0 FOR CONTRACT/SOLICITATION NUMBER MDA414-97-PD514.

==================  Physical/Chemical Properties  ==================

HCC:N1
Vapor Pres:NEGLIGIBLE
Spec Gravity:>1.00
Solubility in Water:APPRECIABLE
Appearance and Odor:SOLID, WHITE, ODORLESS.
Percent Volatiles by Volume:NEGL

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SULFUR DIOXIDE, CARBON DIOXIDE. CARBON
    MONOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MAY BE SUBJECT
    TO NATIONAL, STATE OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE AMOUNTS
    OF WATER.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.