ACE HARDWARE CORP/PAINT DIV -- 280A110, 5-STAR PASTE WOOD FILLER -- 8010-00N029008
=====================  Product Identification  =====================

Product ID:280A110, 5-STAR PASTE WOOD FILLER
MSDS Date:10/01/1986
FSC:8010
NIIN:00N029008
=== Responsible Party ===
Company Name:ACE HARDWARE CORP/PAINT DIV
Address:21901 SOUTH CENTRAL AVENUE
City:MATTESON
State:IL
ZIP:60443
Country:US
Info Phone Num:312-720-0600
Emergency Phone Num:312-720-0600
CAGE:ACEHA
=== Contractor Identification ===
Company Name:ACE HARDWARE CORPORATION
Address:21901 SOUTH CENTRAL AVENUE
City:MATTESON
State:IL
ZIP:60443
Country:US
Phone:708-720-0600
CAGE:ACEHA

=============  Composition/Information on Ingredients  =============

Ingred Name:MINERAL SPIRITS. VP: 2 MMHG.
CAS:64742-47-8
Fraction by Wt: 12.2%
OSHA PEL:500 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

Ingred Name:VM&P NAPHTHA. VP: 33.
CAS:64742-48-9
Fraction by Wt: 0.5%
OSHA PEL:300 PPM
ACGIH TLV:300 PPM

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION IS ANESTHETIC. IRRITATION
    OF RESPIRATORY TRACT OR NERVOUS SYSTEM DEPRESSION. HEADACHE,
    DIZZINESS, NAUSEA, CONFUSION, UNCONSCIOUSNESS OR COMA. SKIN OR EYE:
    PRIMARY IRRITATION. CHRONIC: REPOR TS HAVE ASSOCIATED REPEATED AND
    PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT
    BRAIN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: AND NERVOUS SYSTEM DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHALATION: REMOVE FROM EXPOSURE, RESTORE BREATHING, KEEP
    WARM AND QUIET, NOTIFY PHYSICIAN. EYE: FLUSH IMMEDIATELY WITH
    RUNNING WATER FOR AT LEAST 15 MINUTES. SKIN: WASH WITH SOAP AND
    WATER AND APPLY  SKIN CREAM. INGESTION: CALL MD IMMEDIATELY .
    NOTIFY PHYSICIAN IN ALL CASES.

=====================  Fire Fighting Measures  =====================

Flash Point:53.0F,11.7C
Lower Limits:0.7%
Extinguishing Media:FOAM, CO2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:DO NOT USE NEAR HEAT, SPARKS, OPEN FLAME,
    OR STATIC DISCHARGE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, FLAMES, HOT
    SURFACES AND ELECTRICAL STATIC OR FRICTIONAL SPARK. AVOID BREATHING
    VAPORS; VENTILATE AREA. REMOVE WITH INERT ABSORBENT AND NONSPARKING
    TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE IN TEMPERATURES ABOVE
    120F. STORE LARGE QUANTITIES IN BUILDINGS DESIGNATED AND PROTECTED
    FOR STORAGE OF NFPA CLASS IA FLAMMABLE LIQUIDS.
Other Precautions:DO NOT USE NEAR OPEN FLAME. DO NOT TAKE INTERNALLY.
    CLOSE CONTAINER AFTER EACH USE. AVOID BREATHING VAPORS. KEEP OUT OF
    REACH OF CHILDREN. CONTAINERS SHOULD BE GROUNDED WHEN POURING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF EYE WATERING, HEADACHE OR DIZZINESS IS
    EXPERIENCED, INCREASE FRESH AIR, OR WEAR NIOSH/MSHA APPROVED
    RESPIRATORY EQUIPMENT (TC 23C OR EQUIVALENT) OR LEAVE AREA.
Ventilation:PROVIDE GENERAL OR DILUTING VENTILATION SUFFICIENT TO KEEP
    VAPOR CONCENTRATION BELOW TLV AND LEL.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:PREVENT PROLONGED SKIN CONTACT WITH
    CONTAMINATED CLOTHING. REMOVE AND WASH CONTAMINATED CLOTHING,
    DISCARD CONTAM SHOES.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

HCC:F3
Boiling Pt:B.P. Text:>244F,>118C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:1.58 
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:12.7

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HIGH TEMPERATURES AND OPEN FLAME.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY YIELD CARBON
    MONOXIDE (AS DURING FIRE).

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE, AND
    FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.