EASTMAN KODAK COMPANY -- 146 2829 28% ACETIC ACID -- 6750-01-412-6606
===================== Product Identification ===================== Product ID:146 2829 28% ACETIC ACID MSDS Date:07/26/2000 FSC:6750 NIIN:01-412-6606 === Responsible Party === Company Name:EASTMAN KODAK COMPANY Address:343 STATE STREET City:ROCHESTER State:NY ZIP:14650 Country:US Info Phone Num:716-477-3194 MSDS :800- 242-2424 Emergency Phone Num:716-722-5151 Preparer's Name:NOT PROVIDED CAGE:19139 === Contractor Identification === Company Name:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS Address:343 STATE ST Box:City:ROCHESTER State:NY ZIP:14650-1115 Country:US Phone:716-722-5151/(800) 242-2424 CAGE:19139 Company Name:EASTMAN KODAK CO US CUSTOMER SERVICE/GOVERNMENT SALES Address:800 LEE RD Box:City:ROCHESTER State:NY ZIP:14650-3129 Country:US Phone:800-828-6203 CAGE:5K871 ============= Composition/Information on Ingredients ============= Ingred Name:WATER CAS:7732-18-5 RTECS #:ZC0110000 Minumum % Wt:70. Maxumum % Wt:75. Other REC Limits:NOT PROVIDED Code:F Code:F Ingred Name:ACETIC ACID CAS:64-19-7 RTECS #:AF1225000 Minumum % Wt:25. Maxumum % Wt:30. Other REC Limits:NOT PROVIDED OSHA PEL:25 MG/M3;10 PPM ACGIH TLV:25 MG/M3;10 PPM ACGIH STEL:37 MG/M3;15 PPM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS ===================== Hazards Identification ===================== LD50 LC50 Mixture:ORAL LD-50 (RAT): > 3.2 ML/KG Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:EFFECTS OF EXPOSURE: INHALATION: VAPOR EXTREMELY IRRITATING. EYES: CAUSES SEVERE BURNS. VAPOR EXTREMELY IRRITATING. SKIN: CAUSES SEVERE BURNS. INGESTION: MAY BE FATAL OR HARMFUL IF SWALLOWED. MAY CAUS E BURNS OF THE GASTROINTESTINAL TRACT IF SWALLOWED. Explanation of Carcinogenicity:CARCINOGENICITY CLASSIFICATION (COMPONENTS PRESENT AT 0.1% OR MORE): - INTERNATIONAL AGENCY FOR RESEARCH ON CANCER (IARC): NONE - AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS (ACGIH): NON E - NATIONAL TOXICOLOGY PROGRAM (NTP): NONE - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA): NONE Effects of Overexposure:INHALATION: VAPOR EXTREMELY IRRITATING. EYES: CAUSES SEVERE BURNS. VAPOR EXTREMELY IRRITATING. SKIN: CAUSES SEVERE BURNS. INGESTION: MAY BE FATAL OR HARMFUL IF SWALLOWED. MAY CAUSE BURNS OF THE GASTRO INTESTINAL TRACT IF SWALLOWED. Medical Cond Aggravated by Exposure:NOT PROVIDED ======================= First Aid Measures ======================= First Aid:INHALATION: MOVE TO FRESH AIR. IF BREATHING IS DIFFICULT, GIVE OXYGEN. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. GET MEDICAL ATTENTION IMMEDIATELY. EYES: IMMEDIATELY FLUSH WITH PLENTY OF WATER FO R AT LEAST 15 MINUTES. GET MEDICAL ATTENTION IMMEDIATELY. SKIN: IMMEDIATELY FLUSH WITH WATER FOR AT LEAST 15 MINUTES WHILE REMOVING CONTAMINATED CLOTHING AND SHOES. GET MEDICAL ATTENTION IMMEDIATELY. WASH CONTAMINATED CLOTHING BEFORE REUSE. CLEAN CONTAMINATED SHOES. INGESTION: DO NOT INDUCE VOMITING. GIVE VICTIM A GLASS OF WATER. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. CALL PHYSICIA N OR POISON CONTROL CENTER IMMEDIATELY. ===================== Fire Fighting Measures ===================== Flash Point:NONE Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE. Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND PROTECTIVE CLOTHING. Unusual Fire/Explosion Hazard:NONE ================== Accidental Release Measures ================== Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER. OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT MATERIAL, THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE THOROUGHLY TO REMOVE RESIDUAL CONTAMINATION. Neutralizing Agent:SODIUM BICARBONATE ====================== Handling and Storage ====================== Handling and Storage Precautions:KEEP CONTAINER CLOSED. Other Precautions:DO NOT BREATHE VAPOR AT CONCENTRATIONS GREATER THAN THE EXPOSURE LIMITS. DO NOT GET IN EYES, ON SKIN, ON CLOTHING. USE ONLY WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER HANDLING. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:IF ENGINEERING CONTROLS DO NOT MAINTAIN AIRBORNE CONCENTRATIONS BELOW RECOMMENDED EXPOSURE LIMITS, AN APPROVED RESPIRATOR MUST BE WORN. RESPIRATOR TYPE: FULL-FACE ORGANIC VAPOR CARTRIDGE. IF RESPIRATO RS ARE USED, A PROGRAM SHOULD BE INSTITUTED TO ASSURE COMPLIANCE WITH OSHA STANDARD 29 CFR 1910.134. Ventilation:USE PROCESS ENCLOSURES, LOCAL EXHAUST VENTILATION, OR OTHER ENGINEERING CONTROLS TO MAINTAIN AIRBORNE LEVELS BELOW RECOMMENDED EXPOSURE LIMITS. Protective Gloves:WEAR IMPERVIOUS GLOVES AND PROTECTIVE CLOTHING APPROPRIATE FOR RISK OF EXPOSURE Eye Protection:IF A FULL-FACE RESPIRATOR IS NOT WORN, WEAR VAPOR-TIGHT CHEMICAL GOGGLES. Other Protective Equipment:EYE BATH, WASHING FACILITIES, SAFETY SHOWER Work Hygienic Practices:NOT PROVIDED Supplemental Safety and Health ABBREVIATION: N/A=NOT APPLICABLE OR NOT AVAILABLE. N/K=UNKNOWN. N/P=NOT PROVIDED. N/R=NOT RELEVANT. N/D=NOT DETERMINED. N/E=NOT ESTABLISHED. ================== Physical/Chemical Properties ================== HCC:C2 NRC/State Lic Num:NOT RELEVANT Boiling Pt:>100.C, 212.F Melt/Freeze Pt:M.P/F.P Text:NOT PROVIDED Decomp Temp:Decomp Text:NOT PROVIDED Vapor Pres:(68F):24 MBAR (18 MM HG) Vapor Density:1.0 Spec Gravity:1.036 pH:3.0 Viscosity:NOT PROVIDED Evaporation Rate & Reference:NOT PROVIDED Solubility in Water:COMPLETE Appearance and Odor:COLORLESS LIQUID - SHARP ODOR Percent Volatiles by Volume:100 Corrosion Rate:NOT PROVIDED ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY REASONABLY COME INTO CONTACT. Stability Condition to Avoid:NOT PROVIDED Hazardous Decomposition Products:NOT PROVIDED =================== Toxicological Information =================== Toxicological Information:EFFECTS OF EXPOSURE: ACUTE OVEREXPOSURE TO EXTREMELY HIGH AIRBORNE CONCENTRATIONS OF RESPIRATORY IRRITANTS HAS BEEN ASSOCIATED WITH DEVELOPMENT OF AN ASTHMA-LIKE REACTIVE AIRWAYS SYNDROME (RADS) IN SU SCEPTIBLE INDIVIDUALS. EXTREMELY HIGH AIRBORNE CONCENTRATIONS ARE NOT GENERATED DURING NORMAL CONDITIONS OF USE BUT MAY OCCUR FOLLOWING A SPILL. THE POTENTIAL TO GENERATE EXTREMELY HIGH AIRBORNE CONC ENTRATIONS IN A SPILL SITUATION DEPENDS UPON PHYSICAL FACTORS SUCH AS THE CONCENTRATION OF THE SOLUTION, THE VOLUME OF THE SPILL, THE SURFACE AREA OF THE SPILL, THE SIZE OF ROOM WHERE THE SPILL OCCURE D, AND VENTILATION RATE IN THE ROOM. ===================== Ecological Information ===================== Ecological:THE FOLLOWING PROPERTIES ARE ESTIMATED FROM THE COMPONENTS OF THE PREPARATIONS. POTENTIAL TOXICITY: FISH LC50 MG/L: >100. DAPHNID EC50 MG/L: >100. ALGAL IC50 MG/L: >100 ORGANICS RE ADILY DEGRADABLE YES (7 DAYS) (>70%): POTENTIAL BIOACCUMULATION: LOG POW <1 COD (APPROXIMATE G/L): 300 BOD5 (APPROXIMATE G/L): 215 POTENTIAL TOXICITY WASTE TREATMENT MICROORGANISMS >100 EC50 (MG/L): ==================== Disposal Considerations ==================== Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT TO NATIONAL, STATE, OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER. =================== MSDS Transport Information =================== Transport Information:FOR TRANSPORTATION INFORMATION REGARDING THIS PRODUCT CALL THE KODAK WORLDWIDE TRANSPORTATION HAZMAT HOT LINE: (716) 722-2400 BETWEEN 8 A.M. AND 5 P.M. (EASTERN STANDARD TIME), MONDAY THROUGH FRIDAY . ===================== Regulatory Information ===================== SARA Title III Information:CHEMICAL(S) SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OR TITLE III OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT (SARA) OF 1986 AND 40 CFR PART 372: NONE Federal Regulatory Information:NOT PROVIDED State Regulatory Information:MATERIAL(S) KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER: NONE - MATERIAL(S) KNOWN TO THE STATE OF CALIFORNIA TO CAUSE ADVERSE REPRODUCTIVE EFFECTS: NONE ======================= Other Information ======================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.